120 V AC and 9 V Battery Backup
Dual Sensor
Smoke Alarm
®
Photoelectric / Ionization with Hush Control Feature
Alarm Manual
Model PI2000CA
Ionization sensing alarms may detect invisible fire
particles (associated with fast flaming fires) sooner
SINGLE AND/ OR
MULTIPLE STATION
SMOKE ALARM
than photoelectric alarms. Photoelectric sensing
alarms may detect visible fire particles (associated
with slow smoldering fires) sooner than ionization
alarms. Home fires develop in different ways and
are often unpredictable. For maximum protection,
Kidde recommends that both Ionization and
Photoelectric alarms be installed.
Download from Www.Somanuals.com. All Manuals Search And Download
Installation
This unit is suitable as a single station and/or multiple
station alarm (interconnects with up to 24 devices), and
has a five-year limited warranty.
IMPORTANT:This unit is only approved to interconnect
with the Kidde line of products. It is not approved to
interconnect with any other manufacturer’s products.
This alarm is interconnect compatible with the following
alarms and accessories:
Smoke alarms:
1235CA, 1275CA, 1276CA, 1285CA,
i12020CA, i12040CA, i12060CA,
PE120CA, PI2000CA
Smoke/CO alarms: KN-COSM-IBCA, KN-COSM-ICA
CO alarms:
Relay modules:
Heat alarm:
Strobe Light:
KN-COB-ICB-CA, KN-COB-IC-CA
120X, SM120X, CO120X
HD135FCA
SL177I
Refer to respective manuals for specific application
information.
This product is designed to detect products of combustion
using both an ionization sensor and a photoelectric sensor.
The ionization sensor contains 0.9 microcurie of Americium
241, a radioactive material. Distributed under U.S. NRC
License No. 32-23858-01E. Manufactured in compliance
with U.S. NRC safety criteria in 10 CFR 32.27. The
purchaser is exempt from any regulatory requirements. Do
not try to repair the smoke alarm yourself. Refer to the
instructions in Warranty for service.
ELECTRICAL RATING: 120 V AC, 60 HZ, 80 mA maximum
per alarm (maximum 80 mA for originating unit with 24
devices interconnected).
WARNING! Battery door will not close unless battery is present.
Removal of the smoke alarm battery and disconnecting or loss of
A.C power will render the smoke alarm inoperative.
IMPORTANT! Read all instructions before installation and keep
this manual near the alarm for future reference.
Download from Www.Somanuals.com. All Manuals Search And Download
2
Installation
Recommended Locations
• Locate the first alarm in the immediate area of the
bedrooms. Try to monitor the exit path, as the
bedrooms are usually farthest from the exit. If more
than one sleeping area exists, locate additional alarms in
each sleeping area (Image 1A).
• Locate additional alarms to monitor any stairway as
stairways act like chimneys for smoke and heat.
• Locate at least one alarm on every floor level (Image 1B).
• Locate an alarm in every bedroom.
• Locate an alarm in every room where electrical
appliances are operated (i.e. portable heaters or
humidifiers).
• Locate an alarm in every room where someone sleeps
with the door closed. The closed door may prevent an
alarm not located in that room from waking the sleeper.
• Smoke, heat, and combustion products rise to the
ceiling and spread horizontally. Mounting the smoke
alarm on the ceiling in the centre of the room places it
closest to all points in the room. Ceiling mounting is
preferred in ordinary residential construction.
• When mounting an alarm on the ceiling, locate it at a
minimum of 10 cm (4") from the side wall (Image 2A).
• When mounting the alarm on the wall, use an inside
wall with the top edge of the alarm at a minimum of 10
cm (4") and a maximum of 30.5 cm (12") below the
ceiling (Image 2A).
• Put smoke alarms at both ends of a bedroom hallway
or large room if the hallway or room is more than 9.1 m
(30') long.
• For mobile home installation, select locations carefully
to avoid thermal barriers that may form at the ceiling.
For more details, see Mobile Homes.
Download from Www.Somanuals.com. All Manuals Search And Download
3
Installation
DINING
ROOM
KITCHEN
BEDROOM BEDROOM
BEDROOM
HALL
BEDROOM
KITCHEN
LIVING
ROOM
BEDROOM
LIVING
ROOM
Smoke Alarms for Minimum Protection
Smoke Alarms for Additional Protection
BASEMENT
Ionization Type Smoke Alarm with
Hush® or Photoelectric Type
SINGLE FLOOR PLAN
MULTIPLE FLOOR PLAN
IMAGE 1A
IMAGE 1B
• Install smoke alarms on sloped, peaked or cathedral
ceilings at or within 0.9 m (3') of the highest point
(measured horizontally). NFPA Standard 72 states: “Smoke
alarms in rooms with ceiling slopes greater than 0.3 m in
2.4 m (1' in 8') horizontally shall be located on the high
side of the room.” NFPA Standard 72 states: “A row of
detectors shall be spaced and located within 0.9 m (3') of
the peak of the ceiling measured horizontally” (Image 2B
and Image 2C).
BEDROOM
HALL
MASTER
BEDROOM
FIRE
EXTINGUISHERS
SMOKE
ALARMS
KITCHEN
FAMILY ROOM
GARAGE
CARBON
MONOXIDE
ALARMS
BASEMENT
WORKSHOP
TALKING
SMOKE/CO
ALARM
IMAGE 1C
TOTAL HOME PROTECTION
Download from Www.Somanuals.com. All Manuals Search And Download
4
Installation
Locations to Avoid
• Do not install within 0.9 m (3') of the following: The
door to a kitchen, or a bathroom that contains a tub or
shower, forced air supply ducts used for heating or
cooling, ceiling or whole house ventilating fans, or
other high, air-flow areas.
• Do not place the alarm where drapes or other objects
will block the sensor. Smoke must be able to reach the
sensor to accurately detect conditions.
• Do not install in peaks of vaulted ceilings, “A” frame
ceilings or gabled roofs. (Less than 10 cm (4") from the
peak of an “A” frame type ceiling.)
• Install at least 30.5 cm (12") away from fluorescent
lights as electronic noise may cause nuisance alarms.
• Keep out of insect infested areas. Avoid excessively
dusty, dirty or greasy areas. Dust particles may cause
nuisance alarms or failure to alarm.
• Extreme temperatures may effect the sensitivity of the
alarm. Do not install in areas where the temperature is
colder than 4.4°C (40°F) or hotter than 37.8°C (100°F),
such as garages or unfinished attics.
• Do not install in areas where the relative humidity (RH)
is greater than 85%. Very humid areas, with moisture or
steam, can cause nuisance alarms.
• Avoid placing ionization smoke alarms in kitchen areas.
Normal cooking may cause nuisance alarms. If a
®
kitchen alarm is desired, it should have Hush control
feature or be a photoelectric type.
• Do not place in the garage. Particles of combustion are
present when you start your automobile.
• Smoke alarms are not to be used with detector guards
unless the combination (alarm and guard) has been
evaluated and found suitable for that purpose.
Download from Www.Somanuals.com. All Manuals Search And Download
5
Installation
10 cm (4”)
MINIMUM
CEILING
IMAGE 2A
NEVER HERE
BEST
PLACEMENT
ACCEPTABLE
PLACEMENT
SIDE WALL
NOT IN
THIS AREA
IMAGE 2B
10 cm (4”)
ANYWHERE IN THIS
AREA
0.9 m (3’)
0.9 m (3’)
HORIZONTAL DISTANCE FROM PEAK
IMAGE 2C
NOT IN
THIS AREA
ANYWHERE IN THIS
AREA
10 cm (4”)
0.9 m (3’)
Download from Www.Somanuals.com. All Manuals Search And Download
6
Installation
Mobile Homes
Modern mobile homes have been designed to be energy efficient.
Install smoke alarms as recommended in Recommended Locations and
Image 2A.
In older mobile homes that are not well-insulated compared to
present standards, extreme heat or cold can be transferred from the
outside to the inside through poorly insulated walls and roof. This
may create a thermal barrier that can prevent the smoke from
reaching an alarm mounted on the ceiling. In such units, install the
smoke alarm on an inside wall with the top edge of the alarm at a
minimum of 10 cm (4") and a maximum of 30.5 cm (12") below the
ceiling (Image 2A).
If you are not sure about the insulation in your mobile home, or if
you notice that the outer walls and ceiling are either hot or cold,
install the alarm on an inside wall. For minimum protection, install at
least one alarm close to the bedrooms. For additional protection, see
Image 1A.
WARNING: Test your smoke alarm operation after R.V. or mobile home vehicle
has been in storage, before each trip and at least once a week during use.
Wiring Requirements
• This smoke alarm should be installed on a CSA listed or recognized
junction box. All connections should be made by a qualified
electrician and all wiring used shall be in accordance with articles
210 and 300.3(B) of the U.S. National Electrical Code ANSI/NFPA
70, NFPA 72 and/or any other codes having jurisdiction in your
area. The multiple station interconnect wiring must be run in the
same raceway or cable as the AC power wiring to the alarms. In
addition, the resistance of the interconnect wiring shall be a
maximum of 10 ohms.
• The appropriate power source is 120 Volt AC Single Phase supplied
from a non-switchable circuit which is not protected by a ground
fault interrupter.
• WARNING: The alarm should not be operated on power derived
from a square wave, modified square wave or modified sine wave
inverter. These power sources produce high peak voltages that will
damage the alarm. These types of inverters are sometimes used to
supply power to the structure in off grid installations, such as solar
or wind derived power sources.
Download from Www.Somanuals.com. All Manuals Search And Download
7
Installation
Wiring Instructions
CAUTION! Turn off the main power to the circuit before wiring
the alarm.
• For alarms that are used as single station, DO NOT CONNECT
THE RED WIRE TO ANYTHING. Leave the red wire insulating
cap in place to make certain that the red wire cannot contact
any metal parts or the electrical box.
• When alarms are interconnected, all interconnected units must
be powered from a single circuit.
• A maximum of 24 Kidde devices may be interconnected in a
multiple station arrangement. The interconnect system should
not exceed the NFPA interconnect limit of 12 smoke alarms
and/or 18 alarms total (smoke, heat, carbon monoxide, etc.)
With 18 alarms interconnected, it is still possible to interconnect
up to a total of 6 remote signaling devices and/or relay modules.
CAUTION! Kidde alarm and accessories CAN ONLY BE
interconnected with other Kidde alarms and accessories as well
as specified brands and models of interconnect compatible alarms.
Connection of Kidde products to a non-specified manufacturer’s
interconnect system, or connection with non-specified equipment
from another manufacturer into an existing Kidde system could
result in nuisance alarming, failure to alarm, or damage to one
or all of the devices in the interconnect system. Refer to the
User’s Guide supplied with each Kidde product for interconnect
compatible models, brands, and devices.
• When mixing models which have battery backup with models
without battery backup, be advised that the models without
battery backup will not respond during an AC power failure.
• The maximum wire run distance between the first and last
unit in an interconnected system is 305 m (1000').
• Image 3 illustrates interconnection wiring. Improper connection
will result in damage to the alarm, failure to operate, or a
shock hazard.
• Make certain alarms are wired to a continuous (non-switched)
power line. NOTE: Use standard CSA listed household wire
(as required by local codes) available at all electrical supply
stores and most hardware stores.
Download from Www.Somanuals.com. All Manuals Search And Download
8
Installation
IMAGE 3
INTERCONNECT WIRING
Download from Www.Somanuals.com. All Manuals Search And Download
9
Installation
Mounting
CAUTION: This unit is sealed. The cover is not removable!
• Remove the mounting plate from the back of the alarm by
holding the mounting plate and twisting the alarm in the
direction indicated by the “OFF” arrow on the alarm cover.
• After selecting the proper smoke alarm location as described
previously, and wiring the AC Quick-Connect wire harness as
described in Wiring Instructions, attach the mounting plate to
the electrical box (Image 4B).
A
A
“A” LINE
ALIGNMENT MARKS
IMAGE 4A
IMAGE 4B
Remove
Install
WALL MOUNTING
POSITION
ROTATE TO MOUNT OR
TO REMOVE
IMAGE 4C
IMAGE 4D
Download from Www.Somanuals.com. All Manuals Search And Download
10
Installation
• Pull the AC Quick-Connect wire harness through the
center hole in the mounting bracket and secure the
bracket, making sure that the mounting screws are
positioned in the small ends of the keyholes before
tightening.
• Plug the AC Quick-Connect wire harness into the back
of the alarm (Image 5), making sure that the locks on
the connector snap into place. Then push the excess
wire back into the electrical box through the hole in the
center of the mounting plate.
• Install the alarm on the mounting plate and rotate the
alarm in the direction of the “ON” arrow on the cover
until the alarm ratchets into place (Image 4D). This
ratcheting function allows for aesthetic alignment. Note:
The alarm will attach to the mounting plate in 4
positions (every 90°).
• Turn on the AC power. The green AC Power On indicator
should be lit when the alarm is operating from AC power.
IMAGE 5
ATTACHING THE AC QUICK-CONNECT WIRE HARNESS
Download from Www.Somanuals.com. All Manuals Search And Download
11
Installation
Battery
This unit will not function without a properly installed
battery. When installing a battery, press the battery
reminder tab down into the battery compartment and
install the battery (See Image 6A and 6B). For initial
installation a pre-installed 9 V battery is included with a
battery pull tab that allows for easy connection.
CAUTION: If the battery reminder tab is not held down in the
battery compartment by the battery, the battery door will not
close and the unit will not attach to the mounting plate.
Battery
tab
IMAGE 6A
IMAGE 6B
Testing
• After installation, test your alarm by depressing and
holding down the test button for 5 seconds or until the
alarm sounds.
CAUTION: Due to the loudness (85 decibels) of the alarm, always
stand an arms-length away from the unit when testing.
Operation
The smoke alarm is operating once a fresh battery is installed
and testing is complete. When the smoke alarm ionization
sensor chamber senses products of combustion, the horn will
sound a loud (85 db) alarm until the sensing chamber is
cleared of smoke particles.
Download from Www.Somanuals.com. All Manuals Search And Dow1nl2oad
Operation
®
Hush Control Feature
Smoke alarms are designed to minimize nuisance alarms.
Cigarette smoke will not normally set off the alarm, unless
the smoke is blown directly into the alarm. Combustion
particles from cooking may set off the alarm if the alarm is
located close to the cooking area. Large quantities of
combustible particles are generated from spills or when
broiling. Using the fan on a range hood that vents to the
outside (non-recirculating type) will also help remove
®
these combustible particles from the kitchen. The Hush
button is extremely useful in a kitchen area or other areas
prone to nuisance alarms.
®
The Hush feature has the capability of temporarily
desensitizing the smoke alarm circuit for about 8 minutes.
This feature is to be used only when a known alarm
condition, such as smoke from cooking, activates the alarm.
If the alarm does sound, check for fires first. If a fire is
discovered, get out and call the fire department. If no fire
is present, check to see if one of the reasons listed in
Locations to Avoid may have caused the alarm.
®
The smoke alarm is desensitized by pushing the Hush
button on the smoke alarm cover. If the smoke is not too
dense, the alarm will silence immediately and the red LED
will flash every 2 seconds for approximately 8 minutes. This
indicates that the alarm is in a temporarily desensitized
condition. The smoke alarm will automatically reset after
approximately 8 minutes. If after this period particles of
combustion are still present, the alarm will sound again.
®
The Hush feature can be used repeatedly until the air has
been cleared of the condition causing the alarm. Pushing
the Test button on the alarm will end the alarm silencing
period.
NOTE: Dense smoke will override the Hush® feature and sound a
continuous alarm.
CAUTION: Before using the Hush® feature, identify the source of
the smoke and be certain a safe condition exists.
Do1w3nload from Www.Somanuals.com. All Manuals Search And Download
Operation
Alarm Tamper-Resist Feature
This alarm has a tamper-resist feature. This feature will
help deter children or others from removing the alarm
from the mounting plate.
Activate the tamper-resist feature by breaking off the four
posts in the square holes in the mounting plate (see Image 7A).
Rotate the alarm onto the mounting plate until you hear
the tamper-resist tab snap into place, locking the alarm. To
remove the alarm, press on the tamper resist tab and
rotate the alarm off the mounting plate.
LOCATION
OF POSTS
A
A
IMAGE 7A
IMAGE 7B
IMAGE 7C
IMAGE 7D
Download from Www.Somanuals.com. All Manuals Search And Download
14
Operation
LED Indicators
This smoke alarm is equipped with red and green LED
indicators. The red LED is located under the test button and
has several modes of operation. The green LED is located
®
under the Hush button and indicates the presence of AC
power.
Standby Condition
The red LED will flash every 30–40
seconds to indicate that the smoke
alarm is operating properly. The green
LED will be lit, indicating the presence
of AC power.
Alarm Condition
When the alarm senses particles of
combustion and goes into alarm, the
red LED will flash rapidly (once every
two seconds). The rapid flashing LED
and temporal alarm will continue
until the air is cleared.
Hush Condition
The red LED will flash every 2 seconds
®
as long as the alarm is in Hush mode.
Low Battery Condition The red LED flash will be accompanied
by an audible chirp. Replace the
battery when this condition occurs.
Alarm Memory
This smoke alarm is equipped with
an alarm memory which provides a
visual indication when an alarm has
been activated. A lit red LED
indicates the memory condition. The
memory will remain activated until it
is reset by pushing the test button.
Smoke Sensing Chamber Operation
The alarm will “chirp” if any of the components in the smoke
sensing chamber fail. This chirp will occur between the
flashes of the red LED indicator light. If the “chirp” occurs at
the same time as the red LED flash, see Battery Replacement
section for more information.
Do1w5nload from Www.Somanuals.com. All Manuals Search And Download
Operation
When Units Are Interconnected
Only the red LED of the alarm “which senses the smoke” or
“is being tested” (the originating unit) will flash rapidly. All
other units in the interconnect system will sound an alarm
but their red LED’s will NOT flash rapidly.
Testing
Test by pushing the Test button on the cover and hold
it down for a minimum of 5 seconds. This will sound
the alarm if all the electronic circuitry, horn and battery
are working. In an interconnected installation all
interconnected alarms should sound when the test button
on any one of the interconnected alarms is pressed. If
no alarm sounds, the unit has defective batteries or other
failure. DO NOT use an open flame to test your alarm,
you could damage the alarm or ignite combustible
materials and start a structure fire.
Alarm Memory
This smoke alarm is equipped with an alarm memory
feature which produces a visual indication when an alarm
has been activated. A lit red LED indicates the memory
condition. The memory will remain activated until it is
reset by pushing the test button.
Test the alarm weekly to ensure proper operation. Erratic
or low sound coming from your alarm may indicate a
defective alarm, and it should be returned to place of
purchase (see Warranty section).
NOTE: WEEKLY TESTING IS REQUIRED!
Download from Www.Somanuals.com. All Manuals Search And Download
16
Maintenance
Alarm Removal
If the smoke alarm tamper resist feature has been activated, refer
to the alarm tamper-resist feature section for removal instructions.
To remove the alarm from the mounting plate, rotate the alarm
in the direction of the “OFF” arrow on the cover. To
disconnect the AC power harness, squeeze the locking arms
on the sides of the Quick Connector while pulling the
connector away from the bottom of the alarm.
Battery Replacement
To replace or install the batteries you must first remove the
alarm from the mounting plate by following the ALARM
REMOVAL instructions at the beginning of this section. After the
alarm has been removed, you can open the battery door and
install or replace the battery. Battery installation instructions are
provided on the inside of the battery door.
This smoke alarm uses a 9 V alkaline battery (a lithium battery
may also be used). A fresh alkaline battery should last for one
year under normal operating conditions. This alarm has a low
battery monitor circuit which will cause the alarm to “chirp”
approximately every 30 seconds for a minimum of 7 days when
the battery loses power. Replace when this condition occurs.
Use only the following 9 V batteries for replacement:
Alkaline Type
Energizer 522
Duracell MN1604 or MX1604
Gold Peak 1604A
Panasonic 6AM6, 6AM-6, 6AM-6PI,
6AM6X, and 6LR61(GA)
Ultralife U9VL-J
Lithium Type
After installing or changing the battery, reinstall your alarm.Test
your alarm by using the test button and check that the green
LED is on.
Do1w7nload from Www.Somanuals.com. All Manuals Search And Download
Maintenance
WARNING! Use only the batteries specified. Use of different batteries
than the recommended ones, may have a detrimental effect on the
smoke alarm. A good safety measure is to replace the battery at least
once a year, or at the same time you change your clocks for daylight
saving time. Be sure to follow the battery installation instructions
printed on the back of the alarm.
NOTE: WEEKLY TESTING IS REQUIRED!
NOTE: If after battery replacement the alarm continues to chirp,
®
push the Test button. The Hush feature may have been
activated accidently while changing the battery and pushing the
®
Test button will end the Hush cycle.
Cleaning the Alarm
The alarm should be cleaned at least once a year.
• To clean your alarm, remove it from the mounting plate as
outlined in previous sections. You can clean the alarm by
using compressed air or a vacuum cleaner hose with a soft
brush attachment. Blow or vacuum around the perimeter of
the alarm to remove dust and dirt. The outside of the alarm
can be wiped with a damp cloth (do not use a wet cloth to
avoid water entering the unit).
• After cleaning, reinstall your alarm and test your alarm by
using the Test button. If cleaning does not restore the alarm
to normal operation, the alarm should be replaced.
• Do not paint the unit. Paint will seal the vents and interfere
with the sensor’s ability to detect smoke. Never attempt to
disassemble the unit or clean inside. This action will void
your warranty.
Replacing the Alarm
The National Fire Protection Association (NFPA) recommend
replacing this alarm ten years from the date code label (located
on the back of the alarm).
Download from Www.Somanuals.com. All Manuals Search And Download
18
Fire Safety
Limitations of Smoke Alarms
WARNING: Please read carefully and thoroughly.
• NFPA 72 states: Life safety from fire in residential occupancies
is based primarily on early notification to occupants of the
need to escape, followed by the appropriate egress actions
by those occupants. Fire warning systems for dwelling units
are capable of protecting about half of the occupants in
potentially fatal fires. Victims are often intimate with the
fire, too old or young, or physically or mentally impaired
such that they cannot escape even when warned early
enough that escape should be possible. For these people,
other strategies such as protection-in-place or assisted
escape or rescue are necessary.
• Smoke alarms are devices that can provide early
warning of possible fires at a reasonable cost; however,
alarms have sensing limitations. Ionization sensing
alarms may detect invisible fire particles (associated
with fast flaming fires) sooner than photoelectric alarms.
Photoelectric sensing alarms may detect visible fire
particles (associated with slow, smouldering fires)
sooner than ionization alarms. Home fires develop in
different ways and are often unpredictable. For
maximum protection, Kidde recommends that both
ionization and photoelectric alarms be installed.
• A battery powered alarm must have a battery of the
specified type, in good condition and installed properly.
• AC powered alarms (without battery backup) will not
operate if the AC power has been cut off, such as by an
electrical fire or an open fuse.
• Smoke alarms must be tested regularly to make sure the
batteries and the alarm circuits are in good operating
condition.
• Smoke alarms cannot provide an alarm if smoke does
not reach the alarm. Therefore, smoke alarms may not
sense fires starting in chimneys, walls, on roofs, on the
other side of a closed door or on a different floor.
• If the alarm is located outside the bedroom or on a
different floor, it may not wake up a sound sleeper.
Do1w9nload from Www.Somanuals.com. All Manuals Search And Download
Fire Safety
• The use of alcohol or drugs may also impair one’s
ability to hear the smoke alarm. For maximum
protection, a smoke alarm should be installed in each
sleeping area on every level of a home.
• Although smoke alarms can help save lives by providing
an early warning of a fire, they are not a substitute for
an insurance policy. Home owners and renters should
have adequate insurance to protect their lives and property.
Good Safety Habits
Develop and practice a plan of escape!
• Make a floor plan indicating all doors and windows and
at least two (2) escape routes from each room. Second
story windows may need an escape ladder.
• Have a family meeting and discuss your escape plan,
showing everyone what to do in case of fire.
• Determine a place outside your home where you all
can meet if a fire occurs.
• Familiarize everyone with the sound of the smoke alarm
and train them to leave your home when they hear it.
• Practice a fire drill at least every six months, including
fire drills at night. Ensure that small children hear the
alarm and wake when it sounds. They must wake up in
order to execute the escape plan. Practice allows all
occupants to test your plan before an emergency. You
may not be able to reach your children. It is important
they know what to do.
• Install and maintain fire extinguishers on every level of the
home and in the kitchen, basement and garage. Know
how to use a fire extinguisher prior to an emergency.
• Current studies have shown smoke alarms may not
awaken all sleeping individuals, and that it is the
responsibility of individuals in the household that are
capable of assisting others to provide assistance to those
who may not be awakened by the alarm sound, or to
those who may be incapable of safely evacuating the
area unassisted.
Download from Www.Somanuals.com. All Manuals Search And Download
20
Fire Safety
What To Do When The Alarm Sounds
• Alert small children in the home.
• Leave immediately by your escape plan. Every second
counts, so don’t waste time getting dressed or picking
up valuables.
• In leaving, don’t open any inside door without first
feeling its surface. If hot, or if you see smoke seeping
through cracks, don’t open that door! Instead, use your
alternate exit. If the inside of the door is cool, place
your shoulder against it, open it slightly and be ready to
slam it shut if heat and smoke rush in.
• Stay close to the floor if the air is smoky. Breathe
shallowly through a cloth, wet if possible.
• Once outside, go to your selected meeting place and
make sure everyone is there.
• Call the fire department from your neighbor’s home–not
from yours!
• Don’t return to your home until the fire officials say that
it is all right to do so.
There are situations where a smoke alarm may not be
effective to protect against fire as stated in the NFPA
Standard 72. For instance:
a) smoking in bed
b) leaving children home alone
c) cleaning with flammable liquids, such as gasoline.
NRC Information
Ionization type smoke alarms use a very small amount of a
radioactive element in the sensing chamber to enable detection
of visible and invisible combustion products. The radioactive
element is safely contained in the chamber and requires no
adjustments or maintenance. This smoke alarm meets or
exceeds all government standards. It is manufactured and
distributed under license from the U.S. Nuclear Regulatory
Commission.
Download from Www.Somanuals.com. All Manuals Search And Download
21
Fire Safety
Additional Recommendations
The National Fire Protection Association’s Standard 72
provides the following information:
Smoke Detection. Where required by applicable laws,
codes, or standards for the specified occupancy, approved
single- and multiple-station smoke alarms shall be
installed as follows: (1) In all sleeping rooms Exception:
Smoke alarms shall not be required in sleeping rooms in
existing one- and two-family dwelling units. (2) Outside
of each separate sleeping area, in immediate vicinity of
the sleeping rooms. (3) On each level of the dwelling
unit, including basements Exception: In existing one- and
two-family dwelling units, approved smoke alarms
powered by batteries are permitted.
Smoke Detection:Are More Smoke Alarms Desirable?
Required number of smoke alarms (as shown in Image 1A
and Image 1B): The required number of smoke alarms
might not provide reliable early warning protection for
those areas separated by a door from the areas protected
by the required smoke alarms. For this reason, it is
recommended that the householder consider the use of
additional smoke alarms for those areas for increased
protection.
The additional areas include the basement, bedrooms,
dining room, furnace room, utility room, and hallways not
protected by the required smoke alarms. The installation
of the smoke alarms in the kitchen, attic (finished or
unfinished), or garage is normally not recommended, as
these locations occasionally experience conditions that
can result in improper operation.
Alarms should be installed in accordance with the
National Fire Protection Association’s Standard 72 (NFPA,
Batterymarch Park, Quincy, MA 02269).
Notify your local fire department and insurance company
of your smoke alarm installation.
Download from Www.Somanuals.com. All Manuals Search And Download
22
Warranty
If after reviewing this manual you feel that your smoke alarm
is defective in any way, do not tamper with the unit. In many
cases, the quickest way to exchange your alarm is to return it
to the original place of purchase. Alternatively, you may
return it for servicing to Kidde. If you have questions, call
Kidde Customer Service at 1-800-880-6788.
5 Year Limited Warranty
Kidde warrants to the original purchaser that the enclosed
smoke alarm (but not the battery) will be free from defects in
material and workmanship or design under normal use and
service for a period of five years from the date of purchase.
The obligation of Kidde under this warranty is limited to
repairing or replacing the smoke alarm or any part which we
find to be defective in material, workmanship or design, free
of charge to the customer, upon sending the smoke alarm
with proof of date of purchase, postage and return postage
prepaid, to Kidde, Customer Service Department, 130 Esna
Park Drive, Markham, ON L3R 1E3. 1-800-880-6788.
This warranty shall not apply to the smoke alarm if it has
been damaged, modified, abused or altered after the date of
purchase or if it fails to operate due to improper maintenance
or inadequate AC or DC electrical power.
The liability of Kidde or any of its parent or subsidiary corporations
arising from the sale of this smoke alarm or under the terms
of this limited warranty shall not in any case exceed the cost
of replacement of this smoke alarm and, in no case, shall Kidde
or any of its parent or subsidiary corporations be liable for
consequential loss or damages resulting from the failure of this
smoke alarm or for breach of this or any other warranty, express
or implied, even if the loss or damage is caused by the
company’s negligence or fault.
Since some provinces do not allow limitations on the duration
of an implied warranty or do not allow the exclusion or
limitation of incidental or consequential damages, the above
limitations or exclusions may not apply to you. While this
warranty gives you specific legal rights, you may also have
other rights which vary from province to province.
Also, Kidde makes no warranty, express or implied, written or
oral, including that of merchantability or fitness for any particular
purpose, with respect to the battery.
The above warranty may not be altered except in writing signed
by both parties hereto.